Coline 6 – advanced linear accelerator for modern radiotherapy |
|
Low energy accelerator Coline 6 with 6 MV photon beam has been designed to treat the most common cancer types and to cover up to 80% of radiotherapy needs. Coline 6 from Mediateka NCBJ on Vimeo. Coline 6 is be available in two versions and with a number of options:
Both models of Coline 6 take a full advantage of the precision and reliability of Polkam treatment tables. Coupling with an external positioning system allows for an easy and efficient control of patient position and even safer therapy. Compact and rigid construction of Coline 6 makes it a suitable replacement for cobalt units. Even the basic model assures lower skin doses, more profitable dose distributions, considerable smaller penumbra and better quality of beam delivery. Patients safety is assured by meeting international requirements established by IEC standards and confirmed by the CE mark. Both models of Coline 6 are upgradable and capable to accommodate the more advanced features. Thus, with Coline 6, the initial investment threshold for the modern treatment techniques will get substantially lowered. Ready to use, easy to control position verification and correction system Modern and friendly user interface of Coline 6 has been designed to take a full advantage of two large screen monitors to provide all important information in an elegant, readable and ergonomic way. The Record and Verify System is compliant with treatment plans recorded in DICOM standard and automatically manages both the EPID and the MLC to provide streamlined user experience combined with a full control of the situation: before, during and after patient irradiation. One-Click sending mechanism allows for an easy transmitting of all settings from RVS to the accelerator. High quality imaging solution Digital x-ray detector is based on monolithic, amorphous silicon flat panel capable to work with energies from 40 keV to 15 MeV. 16-bit resolution (65 536 gray levels) and a frame rate of up to 30 frames per second makes this device to be fully suitable for use with modern radiotherapy techniques while the resolution of 2048x2048 pixels with pixel size of only 200 µm provides great image quality for every single frame. The detector is mounted on a fully motorized, 3 joint arm, the position of which together with all the detector parameters is controlled by the operator with the unified user interface. Clinical applications A new, state-of-the-art multileaf collimator family, specifically designed for Coline 6, allows for a very precise dose delivery, greatly reducing dose delivered to healthy tissues. Working modes include step-and-shoot and dynamic arc therapy, allowing for the effective and straightforward treatment with IMRT and IGRT techniques. Two versions of the MLC are available – Basic and Advanced which is distinguished by a number, width and speed of leaves, making IMRT therapy affordable for a large number of oncology departments.
Equipment specification
Gantry
Collimator (standard)
Multi leaf collimator – Basic
Portal Imaging System – EPID
Download
Head of Coline 6 demonstrator team Eng. Jan Kopeć, MSc Deputy Head of Coline 6 demonstrator team Eng. Kaja Swat, MSc
Gallery |
Project co-financed by European Union via European Regional Development Fund